メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

The efficacy of 320-detector row computed tomography for the assessment of preoperative pulmonary vasculature of candidates for pulmonary segmentectomy

  • Shinya Tane
  • , Yoshiharu Ohno
  • , Daisuke Hokka
  • , Hiroyuki Ogawa
  • , Shunsuke Tauchi
  • , Wataru Nishio
  • , Masahiro Yoshimura
  • , Yutaka Okita
  • , Yoshimasa Maniwa

研究成果: ジャーナルへの寄稿学術論文査読

抄録

OBJECTIVES: The purpose of this study was to compare the efficacy of 320-detector row computed tomography (CT) with that of 64-detector row CT for three-dimensional assessment of pulmonary vasculature of candidates for pulmonary segmentectomy. METHODS: We included 32 patients who underwent both 320- and 64-detector CT before pulmonary segmentectomy, which was performed by cutting the pulmonary artery and bronchi of the affected segment followed by dissection of the intersegmental plane along the intersegmental vein. Before the operation, three-dimensional pulmonary vasculature images were obtained for each patient, and the arteries and intersegmental veins of the affected segments were identified. Two thoracic surgeons independently assessed the vessels with visual scoring systems, and kappa analysis was used to determine interobserver agreement. The Wilcoxon signed-rank test was used to compare the visual scores for the assessment of the visualization capabilities of the two methods. In addition, the final determination of pulmonary vasculature at a given site was made by consensus from thoracic surgeons during operation, and receiver operating characteristic analysis was performed to compare their efficacy of pulmonary vasculature assessment. Sensitivity, specificity and accuracy of either method were also compared by means of McNemar's test. RESULTS: Of the 32 cases, there were no operative complications, but 1 patient died of postoperative idiopathic interstitial pneumonia. Visualization scores for the pulmonary vessels were significantly higher for 320-than those for 64-detector CT (P < 0.0001 for the affected arteries and P < 0.0001 for the intersegmental veins). As for pulmonary vasculature assessment, the areas under the curve showed no statistically significant differences in between the two methods, while the specificity and accuracy of intersegemental vein assessment were significantly better for 320-than those for 64-detector row CT (P<0.05). Interobserver agreement for the assessment yielded by either method was almost perfect for all cases. CONCLUSIONS: Three hundred and twenty-detector row CT is more useful than conventional 64-detector row CT for preoperative three-dimensional assessment of pulmonary vasculature, especially when we identify the intersegmental veins, in candidates for pulmonary segmentectomy.

本文言語英語
ページ(範囲)974-980
ページ数7
ジャーナルInteractive Cardiovascular and Thoracic Surgery
17
6
DOI
出版ステータス出版済み - 12-2013
外部発表はい

All Science Journal Classification (ASJC) codes

  • 外科
  • 呼吸器内科
  • 循環器および心血管医学

フィンガープリント

「The efficacy of 320-detector row computed tomography for the assessment of preoperative pulmonary vasculature of candidates for pulmonary segmentectomy」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル