TY - JOUR
T1 - The First Prospective Study Investigating the Safety and Feasibility of a Spray-Type Adhesion Barrier (AdSpray™) in Minimally Invasive Hepatectomy
T2 - An Analysis of 124 Cases at Our Institution
AU - Kojima, Masayuki
AU - Sugioka, Atsushi
AU - Kato, Yutaro
N1 - Publisher Copyright:
© 2024 by the authors.
PY - 2024/3
Y1 - 2024/3
N2 - (1) Background: With the increasing demand for repeat hepatectomy, preventing perihepatic adhesion formation following initial hepatectomy is crucial. Adhesion-preventative barriers, like the new spray-type AdSprayTM (Terumo Corporation, Tokyo, Japan), have been proposed to reduce adhesion risk. However, data on their safety in minimally invasive hepatectomy (MIH) remain scarce. This is the first prospective study to evaluate the safety and feasibility of AdSprayTM in MIH. (2) Methods: A total of 124 patients who underwent MIH with AdSprayTM and 20 controls were analyzed. Subgroup analysis according to the AdSpray™ application area was conducted. Major complications were assessed using the Clavien–Dindo classification. Moreover, intraperitoneal pressure during AdSpray™ application was monitored in 20 cases. (3) Results: Major complications occurred in 6.4% of the patients, which was comparable to that in open hepatectomy. Intraperitoneal pressure remained stable below 12 mmHg during AdSpray™ application without any complications. No significant difference in complication rates was observed among subgroups. However, a potential increase in intra-abdominal abscess formation was suspected with AdSpray™ application to the resected liver surfaces. (4) Conclusions: AdSpray™ can be safely used in MIH; however, further research is needed to confirm the appropriacy of using AdSpray™, particularly over resected liver surfaces. Overall, AdSpray™ is a promising tool for enhancing the safety of MIH.
AB - (1) Background: With the increasing demand for repeat hepatectomy, preventing perihepatic adhesion formation following initial hepatectomy is crucial. Adhesion-preventative barriers, like the new spray-type AdSprayTM (Terumo Corporation, Tokyo, Japan), have been proposed to reduce adhesion risk. However, data on their safety in minimally invasive hepatectomy (MIH) remain scarce. This is the first prospective study to evaluate the safety and feasibility of AdSprayTM in MIH. (2) Methods: A total of 124 patients who underwent MIH with AdSprayTM and 20 controls were analyzed. Subgroup analysis according to the AdSpray™ application area was conducted. Major complications were assessed using the Clavien–Dindo classification. Moreover, intraperitoneal pressure during AdSpray™ application was monitored in 20 cases. (3) Results: Major complications occurred in 6.4% of the patients, which was comparable to that in open hepatectomy. Intraperitoneal pressure remained stable below 12 mmHg during AdSpray™ application without any complications. No significant difference in complication rates was observed among subgroups. However, a potential increase in intra-abdominal abscess formation was suspected with AdSpray™ application to the resected liver surfaces. (4) Conclusions: AdSpray™ can be safely used in MIH; however, further research is needed to confirm the appropriacy of using AdSpray™, particularly over resected liver surfaces. Overall, AdSpray™ is a promising tool for enhancing the safety of MIH.
UR - http://www.scopus.com/inward/record.url?scp=85188948079&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85188948079&partnerID=8YFLogxK
U2 - 10.3390/jpm14030309
DO - 10.3390/jpm14030309
M3 - Article
AN - SCOPUS:85188948079
SN - 2075-4426
VL - 14
JO - Journal of Personalized Medicine
JF - Journal of Personalized Medicine
IS - 3
M1 - 309
ER -