メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

The utility of cerebral perfusion SPECT analysis using SPM8, eZIS and vbSEE for the diagnosis of multiple system atrophy-parkinsonism

  • Keita Sakurai
  • , Etsuko Imabayashi
  • , Kimiteru Ito
  • , Aya M. Tokumaru
  • , Yoshiyuki Ozawa
  • , Masahiro Muto
  • , Motoo Nakagawa
  • , Kenji Okita
  • , Noriyuki Matsukawa
  • , Yuta Shibamoto

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

5   !!Link opens in a new tab 被引用数 (Scopus)

抄録

Objective: Although a correct diagnosis is important for appropriate management, accurately differentiating between multiple system atrophy with predominant parkinsonism (MSA-P) and Parkinson’s disease (PD) is often difficult because of similarities in the early-stage symptoms. The aim of this study was to evaluate the diagnostic value of cerebral perfusion single photon emission computed tomography (SPECT) and voxel-based analysis for diagnosing MSA-P patients.Methods: Thirty-eight subjects (9 with early-stage MSA-P, 11 with PD, and 18 controls) were included in this study. Z-scores suggestive of hypoperfusion were calculated between patients and controls using statistical parametric mapping (SPM) 8 and easy Z-score imaging system (eZIS) programs. A voxel-based stereotactic extraction estimation (vbSEE) program was performed to determine the target volumes of interest (VOIs) in the putamen, pons, and cerebellum, and quantify Z-scores as “extent” (the rate of voxels with a Z-score >2.0 in these VOIs) and “severity” (average Z-scores in these VOIs). These parameters were used as the determinant in receiver operating characteristic (ROC) analyses.Results: The extent and severity of the cerebellar VOIs were higher in MSA-P patients than in PD patients. In ROC analyses, the extent and severity of the cerebellar VOI exhibited the highest areas under the curves of 0.86 and 0.84, and accuracies of 90 and 90 %, respectively.Conclusions: The diagnostic value of significant cerebellar hypoperfusion was the highest for differentiating MSA-P from PD. This voxel-based analysis of cerebral perfusion SPECT using the SPM8, eZIS, and vbSEE programs is useful for clinically diagnosing MSA-P.

本文言語英語
ページ(範囲)206-213
ページ数8
ジャーナルAnnals of Nuclear Medicine
巻29
号2
DOI
出版ステータス出版済み - 02-2014
外部発表はい

All Science Journal Classification (ASJC) codes

  • 放射線学、核医学およびイメージング

フィンガープリント

「The utility of cerebral perfusion SPECT analysis using SPM8, eZIS and vbSEE for the diagnosis of multiple system atrophy-parkinsonism」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル