メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Treatment of osteo-arthropathy associated with dialysis-related amyloidosis by push/pull HDF

  • T. Shinzato
  • , M. Miwa
  • , S. Nakai
  • , Y. Matsumoto
  • , I. Takai
  • , K. Maeda

研究成果: ジャーナルへの寄稿学術論文査読

抄録

Twelve long-term hemodialysis patients who complained of shoulder joint pain were selected for the present study. In these patients, cuprophane dialyzer which had been employed t date was changed to PAN-22DX hemodiafilter® (polyacrylonitrile). After hemodialysis treatment with the PAN-22DX hemodiafilter for 4 weeks, hemodialysis were switched to the push/pull HDF using the same hemodiafilter and performed for another 4 weeks. The, the treatment was switched back to hemodialysis using the PAN-22 DX hemodiafilter. The patients showed a significant increase in upper arm movement ranges following the switch to push/pull HDF treatment. The increased upper arm movement ranges were retained for nearly 2 weeks even after the switch back to the original hemodialysis. The pretreatment β2- microglobulin concentration decreased following the switch from hemodialysis to push/pull HDF.

本文言語英語
ページ(範囲)162-164
ページ数3
ジャーナルJapanese Journal of Artificial Organs
25
1
出版ステータス出版済み - 1996
外部発表はい