Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimuseluting bioresorbable scaffold and an everolimus-eluting metallic stent: Insights from the randomised ABSORB Japan trial

  • Yoshinobu Onuma
  • , Yohei Sotomi
  • , Hiroki Shiomi
  • , Yukio Ozaki
  • , Atsuro Namiki
  • , Satoshi Yasuda
  • , Takafumi Ueno
  • , Kenji Ando
  • , Jungo Furuya
  • , Keiichi Igarashi
  • , Ken Kozuma
  • , Kengo Tanabe
  • , Hajime Kusano
  • , Richard Rapoza
  • , Jeffrey J. Popma
  • , Gregg W. Stone
  • , Charles Simonton
  • , Patrick W. Serruys
  • , Takeshi Kimura

研究成果: ジャーナルへの寄稿 › 学術論文 › 査読

抄録

Aims: We sought to investigate two-year clinical and serial optical coherence tomography (OCT) outcomes after implantation of a fully bioresorbable vascular scaffold (BVS) or a cobalt-chromium everolimus-eluting stent (CoCr-EES). Methods and results: In the ABSORB Japan trial, 400 patients were randomised in a 2:1 ratio to BVS (N=266) or CoCr-EES (N=134). A pre-specified OCT subgroup (N=125, OCT-1 group) underwent angiography and OCT post procedure and at two years. Overall, the two-year TLF rates were 7.3% and 3.8% in the BVS and CoCr-EES arms (p=0.18), respectively. Very late scaffold thrombosis (VLST) beyond one year was observed in 1.6% (four cases: all in non-OCT-1 subgroups) of the BVS arm, while there was no VLST in the CoCr-EES arm. In three cases, OCT at the time of or shortly after VLST demonstrated strut discontinuities, malapposition and/or uncovered struts. However, the vessel healing by two-year OCT was nearly complete in both BVS and CoCr-EES arms with almost fully covered struts, and minimal malapposition. The flow area by two-year OCT was smaller in the BVS arm than in the CoCr-EES arm, mainly due to tissue growth inside the device. However, there were no differences between the BVS and CoCr-EES with regard to the quality of homogenous tissues growing inside the devices. Conclusions: The rate of TLF was numerically higher in the BVS arm than in the CoCr-EES arm, although this difference was not statistically significant. VLST was observed only in the BVS arm at a rate of 1.6% between one and two years. Further studies are mandatory to investigate the risk of BVS relative to metallic stents for VLST, and the underlying mechanisms of BVS VLST.

本文言語英語
ページ(範囲)1090-1101
ページ数12
ジャーナルEuroIntervention
巻12
号9
DOI
出版ステータス出版済み - 10-2016

All Science Journal Classification (ASJC) codes

  • 循環器および心血管医学

フィンガープリント

「Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimuseluting bioresorbable scaffold and an everolimus-eluting metallic stent: Insights from the randomised ABSORB Japan trial」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル