T1 - Unconstrained Monitoring of Pulse Pressure Waves from the Surface of the Subject's Back
AU - Mito, Akihisa
AU - Hirano, Harutoyo
AU - Hagiyama, Naoki
AU - Soh, Zu
AU - Fujita, Etsunori
AU - Ogura, Yumi
AU - Nakamura, Ryuji
AU - Saeki, Noboru
AU - Kawamoto, Masashi
AU - Yoshizumi, Masao
AU - Tsuji, Toshio
N1 - Publisher Copyright:
© 2019 The Society of Instrument and Control Engineers - SICE.
PY - 2019/9
Y1 - 2019/9
N2 - This paper proposes a novel technique to estimate continuous pulse pressure waves based on aortic pulse waves (APWs) that are measured in an unconstrained manner at the back of a user via an APW sensor. Frequency filtering and rectification are applied to the APWs as a preprocessing step. These preprocessed waves are then converted into continuous pulse pressure waves using a black box model that includes the physical factors of the patient. The black box model is constructed beforehand using the preprocessed APWs and continuous arterial pressure waves measured from other users. The converted pulse pressure waves were then compared with continuous arterial pressure waves measured using a commercial sphygmomanometer to evaluate the accuracy of the proposed method. As a result, the correlation coefficient between the converted waves from the proposed method and the waves measured using the sphygmomanometer was 0.83 or higher and the mean absolute error was 6.07 ± 5.89 mmHg. It was therefore concluded that the proposed method may enable unconstrained measurement of continuous pulse pressure waves.
AB - This paper proposes a novel technique to estimate continuous pulse pressure waves based on aortic pulse waves (APWs) that are measured in an unconstrained manner at the back of a user via an APW sensor. Frequency filtering and rectification are applied to the APWs as a preprocessing step. These preprocessed waves are then converted into continuous pulse pressure waves using a black box model that includes the physical factors of the patient. The black box model is constructed beforehand using the preprocessed APWs and continuous arterial pressure waves measured from other users. The converted pulse pressure waves were then compared with continuous arterial pressure waves measured using a commercial sphygmomanometer to evaluate the accuracy of the proposed method. As a result, the correlation coefficient between the converted waves from the proposed method and the waves measured using the sphygmomanometer was 0.83 or higher and the mean absolute error was 6.07 ± 5.89 mmHg. It was therefore concluded that the proposed method may enable unconstrained measurement of continuous pulse pressure waves.
UR - https://www.scopus.com/pages/publications/85073875859
UR - https://www.scopus.com/pages/publications/85073875859#tab=citedBy
U2 - 10.23919/SICE.2019.8859864
DO - 10.23919/SICE.2019.8859864
M3 - Conference contribution
AN - SCOPUS:85073875859
T3 - 2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2019
SP - 39
EP - 44
BT - 2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 58th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2019
Y2 - 10 September 2019 through 13 September 2019
ER -