Using ultrasonography for vessel diameter assessment to prevent infiltration

Hidenori Tanabe, Toshiaki Takahashi, Ryoko Murayama, Koichi Yabunaka, Makoto Oe, Yuko Matsui, Rika Arai, Miho Uchida, Chieko Komiyama, Hiromi Sanada

研究成果: ジャーナルへの寄稿学術論文査読

31 被引用数 (Scopus)

抄録

Small veins are a risk factor for infiltration. However, there are no data regarding the ideal vein diameter for preventing infiltration. Using ultrasound, vessel diameter and calculated ratios of the vessel diameter to the catheter gauge were measured. The relationship between the ratio and infiltration was assessed to establish a cutoff point. The mean ratio of the infiltration group was significantly smaller than that of the no-infiltration group (P < .01), and the ratio was an independent risk factor according to the multivariable analysis. The ratio of 3.3 was determined to be the cutoff point that enables health care professionals to identify veins appropriately.

本文言語英語
ページ(範囲)105-111
ページ数7
ジャーナルJournal of Infusion Nursing
39
2
DOI
出版ステータス出版済み - 23-03-2016